If the Ground Wire Is Cut, Will the Circuit Breaker Trip?
A Practical MCCB Q&A Guide — Powered by SSPD
Q1: If the ground wire is cut, will the MCCB trip?

Short answer: Not necessarily.
A molded case circuit breaker (MCCB) does not rely on the ground wire to trip. It trips when:
Overcurrent occurs (thermal protection)
Short-circuit occurs (magnetic protection)
Accessories detect a fault (e.g., shunt trip, undervoltage trip)
So if the ground wire is cut, the MCCB may still trip, but only when a live-to-neutral or live-to-live fault occurs.
A ground wire mainly provides a safe path for leakage or fault current. If it is cut, the fault current cannot be safely guided to ground, which increases danger but doesn’t stop MCCB from operating.
Q2: When will an MCCB trip if the ground wire is broken?
Even with a broken ground wire, an MCCB will still trip in these situations:
✔ Short circuit between phase conductors
The magnetic trip reacts instantly (2–3 ms).
✔ Overload on the load side
Thermal trip protects the device from overheating.
✔ Direct contact between phase and neutral
This still generates enough fault current for tripping.
However, what becomes dangerous is this:
✘ Leakage to a metal enclosure may NOT generate enough current to trip.
Without a ground wire, the enclosure stays energized (live), and the MCCB will not detect it.
This is why grounding is essential in LV power distribution systems.
Q3: What does SSPD recommend for proper protection?

As a manufacturer deeply engaged in global low-voltage electrical protection, SSPD recommends a three-layer safety approach:
1. MCCB Overcurrent Protection
SSPD CEZC / CNSX / CVS / CNS series MCCB provide:
18–55 kA breaking capacity
Thermal–magnetic or electronic trip units
High mechanical endurance
Full compatibility with global LV systems
OEM/ODM customization for panel builders and OEM manufacturers
2. Reliable Grounding System
Always ensure the grounding path is:
Low impedance
Properly bonded
Tested periodically (earth resistance < 1–5 Ω depending on local standard)
3. Add an RCCB or Earth Leakage Module (ELCB)
For leakage and electric shock protection, SSPD supports external coordination with:
RCCB
RCBO
Leakage modules designed for MCCB integration (upon request)
With these combined, even if the grounding system fails, leakage protection can still operate.
Q4: How does SSPD MCCB behave during a ground fault?
Case A: Ground wire is intact
Leakage current flows safely to earth →
Fault current rises →
MCCB trips rapidly.
Case B: Ground wire is cut
Leakage current has no path to earth, so:
The enclosure becomes live
Fault current is low
MCCB may not trip
The risk of electric shock increases significantly
This is why SSPD strongly recommends periodic grounding inspection for all customers in the Middle East, Africa, and Southeast Asia—especially in humid, dusty, or outdoor environments.
Q5: What makes SSPD MCCB a safe choice for your electrical system?
SSPD MCCBs are engineered for reliability in harsh global markets:
🔶 High-quality copper contacts
Ensures stable breaking performance even under high ambient temperatures.
🔶 Precise tripping characteristics
Each unit undergoes full calibration and final trip testing.
🔶 Wide accessory options
Shunt trip (MX)
Undervoltage release (MN)
Auxiliary contacts (OF/SD)
Rotary handle
Motorized operation modules
🔶 Customized solutions for panel builders
SSPD supports OEM branding, customized printing, and engineering coordination for switchgear manufacturers.
Q6: What should you do if you suspect the ground wire is broken?
SSPD recommends the following steps:
Immediately stop using the equipment.
Use a multimeter to check continuity of the PE line.
Perform an insulation resistance test (≥1 MΩ recommended).
Inspect terminal blocks and grounding bars in the MCC panel.
Replace oxidized or loose terminals.
If needed, contact an SSPD field engineer or local partner.
Remember:
MCCB can protect your system, but it cannot replace grounding protection.
Final Summary
| Question | Short Answer |
|---|---|
| Will MCCB trip if ground wire is cut? | Not necessarily. Only certain faults still cause tripping. |
| Is it dangerous? | Yes. Equipment casing may become live. |
| What’s the proper protection? | Good grounding + MCCB + leakage protection. |
| Is SSPD suitable for these scenarios? | Yes. SSPD MCCBs offer reliable, customizable protection for global markets. |