SSPD AC contactor CLC1D series are available from 9A-95A. SSPD CLC1D series has exquisite appearance and high quality.
CLC1 |
D09 |
D12 |
D18 |
D25 |
D32 |
D38 |
D40A |
D50A |
D65A |
D80 |
D95 |
|
Rated operational current |
9A |
12A |
18A |
25A |
32A |
38A |
40A |
50A |
65A |
80A |
95A |
|
Control citcuit voltage |
AC 24V, 110V, 220V, 380V, 415V |
|||||||||||
Standard power ratings of |
220V/230V |
2.2 |
3 |
4 |
5.5 |
7.5 |
9 |
11 |
15 |
18.5 |
22 |
25 |
380V/400V |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
22 |
30 |
37 |
45 |
|
415V |
4 |
5.5 |
9 |
11 |
15 |
18.5 |
22 |
25 |
37 |
45 |
45 |
|
440V |
4 |
5.5 |
9 |
11 |
15 |
18.5 |
22 |
3 |
37 |
45 |
45 |
|
500V |
5.5 |
7.5 |
10 |
15 |
18.5 |
18.5 |
22 |
30 |
37 |
55 |
55 |
|
660V/690V |
5.5 |
7.5 |
10 |
15 |
18.5 |
18.5 |
30 |
33 |
37 |
45 |
45 |
|
1000V |
- |
- |
- |
- |
- |
- |
- |
- |
- |
45 |
45 |
Auxiliary contact blocks
Instantaneous auxiliary contact blocks for connection by screw clamp terminals
For use in normal operating environments
Clip-on mounting |
Number of Contacts per block |
Composition |
reference |
||||
|
|
|
|
|
|
||
Front |
1 |
- |
- |
- |
1 |
- |
LADN10 |
- |
- |
- |
- |
1 |
LADN01 |
||
2 |
- |
- |
- |
1 |
1 |
LADN11 |
|
- |
- |
- |
2 |
- |
LADN20 |
||
- |
- |
- |
- |
2 |
LADN02 |
||
4 |
- |
- |
- |
2 |
2 |
LADN22 LADN22S |
|
- |
- |
- |
1 |
3 |
LADN13 |
||
- |
- |
- |
4 |
- |
LADN40 |
||
- |
- |
- |
- |
4 |
LADN04 |
||
- |
- |
- |
3 |
1 |
LADN31 |
||
4 incl. 1N/O & 1N/C make before break |
- |
- |
- |
2 |
2 |
LADN22 |
|
Side (Contact blocks compatible with AC coil ontactors only) |
2 |
- |
- |
- |
1 |
1 |
LAD8N11 |
- |
- |
- |
2 |
- |
LAD8N20 |
||
- |
- |
- |
- |
2 |
LAD8N02 |
||
For terminal referencing conforming to EN 50012 |
|||||||
Front on 3P contactors and 4P contactors 20 to 80A |
2 |
- |
- |
- |
1 |
1 |
LADN11G |
4 |
- |
- |
- |
2 |
2 |
LADN22G |
|
Front on 4P contactors 125 to 200 A |
2 |
- |
- |
- |
1 |
1 |
LADN11P |
4 |
- |
- |
- |
2 |
2 |
LADN22P |
lnstantaneous auxiliary contact blocks for connection by lugs
This type of connection is not possible for blocks with 1 contact or blocks with dust and damp protected contacts. For all other instantaneous auxiliary contact blocks, add the figure 6 to the end of the references selected above.
Example: LADN11 becomes LADN116.
Instantaneous auxiliary contact blocks for connection by spring terminals
This type of connection is not possible for LAD8, LADN with 1 contact or blocks with dust and damp protected contacts. For all other contact blocks, add the figure 3 to the end of the references selected above.
Example: LADN11 becomes LADN113.
Instantaneous auxiliary contact blocks for connection by Faston connectors
This type of connection is not possible for LAD8, LADN with 1 contact or blocks with dust and damp protected contacts. For all other contact blocks, add the figure 9 to the end of the references selected above.
Example: LADN11 becomes LADN119.
Maximum number of auxiliary contacts that can be fitted:
Contactors |
Instantaneous auciliary contacts |
Time delay Front Mounted |
||||||
Type |
Number of poles and size |
Side mounted |
Frount mounted |
|||||
1 contact |
2 contact |
3 contact |
||||||
AC AC/DC |
3P |
LC1D09...D38 |
1 on LH or 1 on RH side |
and |
- |
1 |
or 1 |
or 1 |
LC1D40A...D80A |
1 on LH or 1 on RH side |
and |
- |
1 |
or 1 |
or 1 |
||
LC1D80 AND D95(50/60Hz) |
1 on each side |
or |
1 |
and 1 |
or 1 |
or 1 |
||
LC1D80 AND D95(50 or 60Hz) |
1 on each side |
and |
1 |
and 1 |
or 1 |
or 1 |
||
LC1D115 AND D150 |
1 on LH side |
and |
- |
1 |
or 1 |
or 1 |
||
4P |
LC1DT20...DT40 |
1 on LH side |
and |
- |
1 |
or 1 |
or 1 |
|
LC1DT60A AND DT80A |
1 on LH or 1 on RH side |
and |
- |
1 |
or 1 |
or 1 |
||
LC1D40008, D65008 and D80 |
1 on each side |
or |
1 |
or 1 |
or 1 |
or 1 |
||
LC1D115 |
1 on each side |
and |
1 |
or 1 |
or 1 |
or 1 |
||
DC |
3P |
LC1D09...D38 |
- |
|
- |
1 |
or 1 |
or 1 |
LC1D40A...D80A |
- |
|
- |
1 |
or 1 |
or 1 |
||
LC1D80 and D95 |
- |
|
1 |
or 1 |
or 1 |
or 1 |
||
LC1D115 and D150 |
1 on LH side |
and |
- |
1 |
or 1 |
or 1 |
||
4P |
LC1DT20...DT40 |
- |
|
- |
1 |
or 1 |
or 1 |
|
LC1DT60A and DT80A |
- |
|
- |
1 |
or 1 |
or 1 |
||
LC1D40008, D65008 and D80 |
- |
|
2 |
and 1 |
or 1 |
or 1 |
||
LC1D115 |
1 on each side |
|
- |
and 1 |
or 1 |
or 1 |
||
LC |
3P |
LC1D09...D38 |
- |
|
- |
1 |
- |
- |
4P |
LC1DT20...DT40 |
- |
|
- |
1 |
- |
- |
Dimension CLC1-D09 to D38
Dimension CLC1-D40A to D80A, CLC1-D80 to D95
Mounting CLC1-D09 to D95
Model |
Qty/CTN(pcs) |
GW(kg) |
NW(kg) |
Carton Size(cm) |
CLC1-D09 |
50 |
18.00 |
16.5 |
48.8*26.8*18 |
CLC1-D12 |
50 |
18.00 |
16.5 |
|
CLC1-D18 |
50 |
18.00 |
16.5 |
|
CLC1-D25 |
50 |
21.00 |
19.2 |
51.3*27.8*19.7 |
CLC1-D32 |
50 |
21.00 |
19.2 |
|
CLC1-D38 |
50 |
21.00 |
19.2 |
|
CLC1-D40A |
20 |
19.5 |
17.5 |
48.5*28*28 |
CLC1-50A |
20 |
19.5 |
17.5 |
48.5*28*28 |
CLC1-65A |
20 |
19.5 |
17.5 |
48.5*28*28 |
CLC1-D80 |
20 |
32 |
30 |
48.5*28*28 |
CLC1-D95 |
20 |
32 |
30 |
48.5*28*28 |
We SSPD are excited to announce that Super September is here! This is our biggest promotion event of the year, and we're offering some amazing deals on everything yo...
We are delighted to announce that we will be attending the 23rd China International Industry Fair (CIIF) in Shanghai from September 19 to 23, 2023. CIIF is one of th...
Upon Xi's arrival, the Kremlin Commander greeted him at the drop-off point. President Putin shook hands warmly with Xi Jin ping and posed for a photo. The two heads ...
Contactor belongs to a kind of electrical control components, mainly used to control the on-off of electrical signals, and can control high power electrical load. It...