CLC1D09 To CLC1D95 AC Contactor

CLC1D09 To CLC1D95 AC Contactor
CLC1D09 To CLC1D95 AC Contactor
CLC1D09 To CLC1D95 AC Contactor
CLC1D09 To CLC1D95 AC Contactor

SSPD AC contactor CLC1D series are available from 9A-95A. SSPD CLC1D series has exquisite appearance and high quality.

CLC1 D09 D12 D18 D25 D32 D38 D40A 50A 65A D80 D95
Rated operational current
in AC-3 440V up to
9A 12A 18A 25A 32A 38A 40A 50A 65A 80A 95A
Control citcuit voltage AC 24V,110V,220V,380V,415V
Standard power ratings of
3-phase motors
50-60 Hz in category AC-3
(θ≤ 60 °C)
220V/230V 2.2 3 4 5.5 7.5 9 11 15 18.5 22 25
380V/400V 4 5.5 7.5 11 15 18.5 18.5 22 30 37 45
415V 4 5.5 9 11 15 18.5 22 25 37 45 45
440V 4 5.5 9 11 15 18.5 22 30 37 45 45
500V 5.5 7.5 10 15 18.5 18.5 22 30 37 55 55
660V/690V 5.5 7.5 10 15 18.5 18.5 30 33 37 45 45
1000V - - - - - - - - - 45 45

Auxiliary contact blocks

LADN11,LAD8N11,LA1DX..,LA1DZ..

Instantaneous auxiliary contact blocks for connection by screw clamp terminals

lnstantaneous auxiliary contact blocks for connection by lugs

This type of connection is not possible for blocks with 1 contact or blocks with dust and damp protected contacts. For all other instantaneous auxiliary contact blocks, add the figure 6 to the end of the references selected above.
Example: LADN11 becomes LADN116.

Instantaneous auxiliary contact blocks for connection by spring terminals

This type of connection is not possible for LAD8, LADN with 1 contact or blocks with dust and damp protected contacts. For all other contact blocks, add the figure 3 to the end of the references selected above.
Example: LADN11 becomes LADN113.

Instantaneous auxiliary contact blocks for connection by Faston connectors

This type of connection is not possible for LAD8, LADN with 1 contact or blocks with dust and damp protected contacts. For all other contact blocks, add the figure 9 to the end of the references selected above.
Example: LADN11 becomes LADN119.

Maximum number of auxiliary contacts that can be fitted:

Contactors,Instantaneous auxillary contacts

Dimension CLC1-D09 to D38

Dimension CLC1-D40A to D80A, CLC1-D80 to D95

Mounting CLC1-D09 to D95

Model Qty/CTN(pcs) GW(kg) NW(kg) Carton Size(cm)
CLC1-D09 50 19 17 40.5*25.5*19
CLC1-D12 50 19 17 40.5*25.5*19
CLC1-D18 50 19 17 40.5*25.5*19
CLC1-D25 50 20.5 18.5 46*27*21
CLC1-D32 50 20.5 18.5 46*27*21
CLC1-D38 50 20.5 18.5 46*27*21
CLC1-D40A 20 19.5 17.5 48.5*28*28
CLC1-50A 20 19.5 17.5 48.5*28*28
CLC1-65A 20 19.5 17.5 48.5*28*28
CLC1-D80 20 32 30 48.5*28*28
CLC1-D95 20 32 30 48.5*28*28

News Center

> Why is it necessary to install a rotary handle on the molded case circuit breaker

The rotary handle is used to control the operation of MCCB through rotation control.For molded case circuit breaker, the handle has three terminals: on, off and rese...

> Eurasian Economic Union to develop transport infrastructure

Recently, Eurasian Economic Commission Executive Committee Chairman Miasnikovic said that the member states decided to carry out the construction of transportation i...

> Team Bonding Event of Shendian Electrical

We, Shendian Electrical Co., Ltd. has been focusing on producting low-voltage electrical products for 30 years. Our main products are molded case circuit breakers, a...

> How to choose a suitable molded case circuit breaker in electrical work?

This question is easy to answer, mainly from two aspects of voltage and current. The following mainly analyzes the selection of plastic case circuit breakers for dis...